Pelco Manual C2436M-B (9/02) [ 9 ]
Focus Adjustment for Fixed Focal Length Lens
with Auto Iris
To adjust the focus, it may be necessary to remove the heater board in order to loosen the locking screw
on the bottom of the lens.
To remove the heater board:
1. Disconnect the four-pin heater wiring.
2. Wait for the heater elements to cool if they are hot.
3. Apply pressure and press on the corner of the board.
To adjust the focus:
1. Loosen the locking screw on the bottom of the lens.
2. Move the screw in the slot to bring the picture into focus.
3. Retighten the locking screw.
4. Replace the heater board if it was removed.
5. Reconnect the four-pin heater wiring.
Heater elements could be hot! When camera power is on, use caution when
adjusting the camera.
CAUTION
Switch Settings for Fixed Focal Length Lens
with Auto Iris
Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensation
(factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting conditions
where there are no bright spots that darken other picture details. Manual backlight compensation is used
in fixed lighting conditions to optimize the picture detail when there are bright spots.
ALC/ELC switch: Always ALC
Y/DC switch: Always DC
Auto backlight compensation: BLC switch OFF
ABL switch ON
Manual backlight compensation: BLC switch ON
ABL switch OFF
= SWITCH POSITION
FACTORY SETTINGS
ON
OFF
ALC
Y
BLC
ABL
ELC
DC
OFF
OFF
FOCUS
ADJUSTMENT
SCREW
ADJUSTMENT
SLOT
BOTTOM VIEW OF CAMERA WITH
HEATER BOARD REMOVED
Page view 8
1 2 3 4 5 6 7 8 9 10 11 12

Comments to this Manuals

No comments