Pelco ECM100 User Manual

Browse online or download User Manual for Security camera accessories Pelco ECM100. Pelco ECM100 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Worldwide Headquarters • 3500 Pelco Way • Clovis, California 93612 USA •
www.pelco.com
USA & Canada • Tel: 800/289-9100 • Fax: 800/289-9150
International • Tel: 1-559/292-1981 • Fax: 1-559/348-1120
Pelco, the Pelco logo, Spectra, Genex, Esprit, Camclosure, and Legacy are registered trademarks of Pelco. ©Copyright 2004, Pelco. All rights reserved.
C225M-C (11/04)
Esprit
®
Mounts
EWM, EPM, ECM100, and EPP
®
Important Safety Instructions
1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Use only installation methods and materials capable of supporting four times the maximum specified load.
3. Use stainless steel hardware to fasten the mount to outdoor surfaces.
4. To prevent damage from water leakage when installing a mount outdoors on a roof or wall, apply sealant around the bolt holes between the mount
and mounting surface.
Description
This manual contains the installation instructions for the following Esprit
®
mounts:
EWM Wall Mount Use to mount an Esprit system directly to a load bearing vertical surface.
EPM Pole Mount Use in conjunction with the EWM to mount an Esprit system to a pole.
ECM100 Corner Mount Use in conjunction with the EWM to mount an Esprit system to a building corner.
EPP Pedestal Adapter Use to mount an Esprit system directly to a pedestal mount.
Installation
EWM ESPRIT WALL MOUNT
1. Remove the knockouts from the conduit plate. Use the plate as a
template. Mark the conduit and fastener positions onto the mounting
surface. Prepare the surface.
2. Attach the gasket to the end of the EWM.
3. Install the conduit fittings (not supplied).
If conduit is not used, install
sealing glands
(supplied) on the conduit plate. Thread the wiring/cabling
through the conduit plate/sealing glands and EWM wall mount. Attach
the EWM to the mounting surface with the appropriate hardware (not
supplied). Refer to the manual supplied with the Esprit system to
complete the installation.
NOTE:
Refer to Tables A and B for wiring distances.
Page view 0
1 2 3 4

Summary of Contents

Page 1 - EWM ESPRIT WALL MOUNT

Worldwide Headquarters • 3500 Pelco Way • Clovis, California 93612 USA • www.pelco.com USA & Canada • Tel: 800/289-9100 • Fax: 800/289-9150Inter

Page 2 - ECM100 ESPRIT CORNER MOUNT

EPM ESPRIT POLE MOUNT 1. Thread wiring/cabling through the hole in the pole mount and attach the mount to the pole with three stainless steel straps

Page 3 - Specifications

EPP ESPRIT PEDESTAL ADAPTER 1. Route the wiring/cabling through the pedestal mount and the EPP pedestal adapter.2. Attach the pedestal adapter to th

Page 4 - REVISION HISTORY

4.75(12.07)6.00(15.24)Ø 0.37 (0.94), 8X0.60 (1.52)8.00(20.32)2.00 (5.08)ECM1003.58(9.09)Ø3.00ECM1000.8 X 0.375(2.03 X 0.95)6.00(15.24)0.25(0.64)1.50(3

Comments to this Manuals

No comments