INSTALLATION/OPERATIONC1307M-C (8/07)ES30TI Esprit® with Thermal Imager
10 C1307M-C (8/07)c. Connect the wiring for a 2-wire or 4-wire control system. This step does not apply to Coaxitron® control systems.d. Connect AUX 2
C1307M-C (8/07) 119. Plug the male Esprit system connector, located on the bottom of the pan/tilt, into the female Esprit system connector located on
12 C1307M-C (8/07)TXB Series Translator Board Installation (Optional)Pelco’s TXB Series allows controllers from other companies to communicate with th
C1307M-C (8/07) 13REINSTALLING THE PAN/TILT COVERThe pan/tilt covers must be properly seated and have a tight seal all the way around when installed.F
14 C1307M-C (8/07)OperationCONFIGURATION DISPLAYWhen you apply power to the ES30TI, a configuration screen appears. This screen displays the selected
C1307M-C (8/07) 15OPERATING NOTESENVIRONMENTAL RANGEThe operating temperature ranges from a minimum of -40°F (-40°C) to a maximum of 131°F (55°C) for
16 C1307M-C (8/07)PATTERNSThe Esprit system can do either one full pattern (1.5, 3, or 6 minutes long) or two half patterns (0.75, 1.5, or 3 minutes l
C1307M-C (8/07) 17Programming*These options only appear when AGC Mode is set to Manual.†These options only appear when ROI is set to On.If limit stops
18 C1307M-C (8/07)ACCESSING MAIN MENU (PRESET 95)You can call up the main menu on your monitor by programming (setting or creating) preset 95 (28 if i
C1307M-C (8/07) 19KBD4000/KBD4002/KBD4000V1. Press the SPOT MONITOR key. 2. Enter 95 and then hold the PRESET key (approximately five seconds) until t
20 C1307M-C (8/07)AGC MODEAutomatic gain control generally gives the best results and values for hot bias and contrast. In certain scenes and on certa
C1307M-C (8/07) 21AZ/ELAz/El programs the horizontal display position of the Azimuth*/Elevation† label.NOTE:• Az/El display is not available while you
22 C1307M-C (8/07)AZ/EL LINEAz/El Line controls the vertical display position of the Azimuth/Elevation label. You can display the label on lines 3 thr
C1307M-C (8/07) 23AZIMUTH ZEROAzimuth is the pan angle from 0 to 359 degrees. Azimuth zero is the programmed zero-degree point that is normally set to
24 C1307M-C (8/07)CONTRASTUse the Contrast option to adjust the contrast across the color palette. Increase the Contrast setting to represent midrange
C1307M-C (8/07) 25DIRECTIONDirection programs the horizontal display position of the Direction label (N, NW, NE, …)NOTES: • For direction to be accura
26 C1307M-C (8/07)DIRECTION LINEDirection Line controls the vertical display position of the Direction label. You can display the label on lines 3 thr
C1307M-C (8/07) 27DISPLAY DURATIONDisplay Duration programs the duration the Az/El, Direction, and Zoom labels are displayed on the monitor. The avail
28 C1307M-C (8/07)DISPLAY TYPEDisplay Type programs the specific palette of colors to represent the temperatures in the thermal image. These colors ar
C1307M-C (8/07) 29FLAT FIELD CORRECTION (FFC)Flat Field Correction (FFC) controls how the camera regularly adjusts its thermal settings to optimize it
C1307M-C (8/07) 3ContentsImportant Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30 C1307M-C (8/07)TEMP CHANGETemperature Change sets the increment (in degrees) of change required to automatically trigger the FFC process when the t
C1307M-C (8/07) 31HOT BIASUse the Hot Bias option to adjust how the color palette represents the temperature range of the image. The Hot Bias range is
32 C1307M-C (8/07)LIMIT STOPSThe Limit Stops options control the pan position limit for the camera. You can set different limits for manual operation
C1307M-C (8/07) 33Limit Stops MenuTo program manual limit stops using the Limit Stops menu:1. Program preset 95 (28). The main menu appears.2. Positio
34 C1307M-C (8/07)Limit Stops MenuTo program scan limit stops using the Limit Stops menu:1. Program preset 95 (28). The main menu appears.2. Position
C1307M-C (8/07) 35PARK TIME MINUTESUse this feature to park at the preset 1 position after a specific number of minutes of control inactivity. You can
36 C1307M-C (8/07)PATTERN LENGTHThe Esprit can run either of the following:• One full pattern that is 1.5, 3, or 6 minutes long.• Two half patterns th
C1307M-C (8/07) 37POWER UP MODEUse this feature to execute a specific set of commands following the power up sequence. You can select from the followi
38 C1307M-C (8/07)PROFILEProfile lets you activate a specific group of settings (Sharpness, Hot Bias, Contrast, or AGC Mode), as follows:• Night, Day,
C1307M-C (8/07) 39REGION OF INTERESTThe Region of Interest (ROI) is similar to a light meter zone in a conventional camera. Use it when the heat image
4 C1307M-C (8/07)Scan Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
40 C1307M-C (8/07)ENABLING OR DISABLING ROIYou have to enable the ROI option before you can configure it. ROI is set to OFF by default.To change the R
C1307M-C (8/07) 41RESET CAMERAResetting the camera restarts the camera. The camera peforms its normal power up process.To reset the camera:1. Program
42 C1307M-C (8/07)RESTORE ALL DEFAULTSRestoring all defaults returns the settings on all menus and submenus to their defaults. This function also clea
C1307M-C (8/07) 43RESTORE CAMERA DEFAULTSRestoring camera defaults returns the settings on the Camera menu and its submenus to their defaults. It does
44 C1307M-C (8/07)SAVE PROFILEThe Save Profile feature lets you save a user-defined group of profile settings into either the Custom 1 or the Custom 2
C1307M-C (8/07) 45SCAN SPEEDScan speed controls the movement speed in auto, random, and frame scan modes. You can select from 1 to 40 degrees per seco
46 C1307M-C (8/07)SHARPNESSUse the Sharpness setting to set the digital sharpness of the camera. Settings include Lowest, Low, Medium, High, and Highe
C1307M-C (8/07) 47SPEED PROFILEUse this feature to set the wind speed conditions for the location of the Esprit system. High winds may intefere with h
48 C1307M-C (8/07)TEMP UNITSThe Temp Units setting controls how temperature values are displayed. You can select either Celsius or Fahrenheit. The def
C1307M-C (8/07) 49ZONESBasic rules for setting zones:1. Your controller must support zone operation.2. Refer to the documentation for your control sys
C1307M-C (8/07) 5Important Safety Instructions1. Read these instructions.2. Keep these instructions.3. Heed all warnings.4. Follow all instructions.5.
50 C1307M-C (8/07)ZOOMZoom programs the horizontal display position of the Zoom label. The following settings are available for the Zoom label:• Off:
C1307M-C (8/07) 51ZOOM LINEZoom Line controls the vertical display position of the Zoom label. You can display the label on lines 3 through 10.Line 3
52 C1307M-C (8/07)Maintenance and TroubleshootingMAINTENANCEClean the enclosure window periodically with a mild nonabrasive detergent in water and a s
C1307M-C (8/07) 53Symptom: Ground loopsGround loops are indicated by seeing 60 Hz noise on the video.1. Check for resistance between the grounds of th
54 C1307M-C (8/07)AppendixNOTE: Esprit will sense and automatically select input from Coaxitron control signals in either the standard or extended mod
C1307M-C (8/07) 55NOTE: The Esprit will sense and automatically select input from Coaxitron control signals in either the standard or extended mode. T
56 C1307M-C (8/07)– 112 OFF OFF OFF OFF ON ON ON OFF– 113 ON OFF OFF OFF ON ON ON OFF– 114 OFF ON OFF OFF ON ON ON OFF– 115 ON ON OFF OFF ON ON ON OFF
C1307M-C (8/07) 57– 232 OFF OFF OFF ON OFF ON ON ON– 233 ON OFF OFF ON OFF ON ON ON– 234 OFF ON OFF ON OFF ON ON ON– 235 ON ON OFF ON OFF ON ON ON– 23
58 C1307M-C (8/07)SpecificationsELECTRICALInput Voltage 24, 120, or 230 VAC, 50/60 Hz; switch selectable for 120/230 VAC inputs. Reset feature enabled
PRODUCT WARRANTY AND RETURN INFORMATIONWARRANTYPelco will repair or replace, without charge, any merchandise proved defective in material orworkmanshi
6 C1307M-C (8/07)Regulatory NoticesThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
Worldwide Headquarters3500 Pelco WayClovis, California 93612 USAUSA & CanadaTel: 800/289-9100Fax: 800/289-9150InternationalTel: 1-559/292-1981Fax:
C1307M-C (8/07) 7DescriptionThe ES30TI Series combines the power of an advanced thermal imaging device with the precision of an Esprit® positioning sy
8 C1307M-C (8/07)Installation1. When installing the ES30TI Esprit system, allow for sufficient clearance between the top of the unit and overhead obst
C1307M-C (8/07) 93. Attach the base of the system to an Esprit mount (EWM or EPP) with the three flathead 10-32 x 1/2-inch screws and washers (supplie