14 C311M-L (1/05)
CURRENT READING MENU
The Current Reading menu displays the existing status of temperature, pressure, and dewpoint inside the integrated optics cartridge. An
asterisk displayed to the left of a menu item denotes that an alert condition exists.
Due to the heat emitted from the electronics of the camera, normal temperature operating range is approximately 95°F.
PAN AND TILT FUNCTIONS
Controller Pan Tilt
Type (Capability – 360° Continuous Pan Rotation)** (Viewing Range – +33° to -83°)***
Fixed speed Speed determined by controller Speed determined by controller
*Variable speed 0.1 to 40° per second, depending on joystick and 0.1 to 20° per second, depending on joystick and
zoom positions zoom positions
*Turbo Mode 100° per second Does not affect the tilt speed
*Preset Mode 100° per second 30° per second
* 50 mph wind speed profile.
** If manual limit stops are set, “Pan Limit” appears on your monitor when a limit stop is reached (except when you are programming or
running a pattern). This does not apply to scan limit stops.
*** When the system reaches the upper limit, “Tilt Limit” appears on your monitor (except when you are programming or running a
pattern).
If the proportional pan mode is enabled (refer to
Proportional Pan
in the
Programming
section), the pan and tilt speeds will depend on the
amount of zoom. At telephoto zoom settings, the pan and tilt speeds will be slower for a given amount of joystick deflection than at wide
zoom settings. This keeps the image from moving too fast on the monitor when there is a large amount of zoom. This slowing does not
happen when going to a preset, but does occur in turbo mode when high zoom is selected. The minimum pan and tilt speeds are 0.1
degree per second at full zoom.
SCAN SPEED
Scan speed is adjustable from 1 to 40 degrees per second through the programming menu.
PRESET FUNCTIONS
The Esprit
®
system is capable of going to 64 preset locations, each with a 20-character label. The presets are numbered 1-32 and 35-66.
Refer to the documentation for your control system for programming presets.
If you command the pan and tilt to go to an undefined preset, erratic operation may result.
Presets 33 and 34 are fixed commands, meaning that you cannot program them. Preset 33 is the “flip” command, which will pan the
system 180 degrees. Preset 34 is the “pan zero” command, which will pan the system to the factory-determined zero reference point.
RANDOM, FRAME, AND AUTO SCANNING
Select preset 97 (30) to start random scanning. Select preset 98 (31) to activate frame scanning (three seconds of scanning followed by a
three-second pause). Select preset 99 (32) to start auto (continuous) scanning. Scan limit stops are controlled by software. Refer to the
Limit Stops
section to program the scan limit stops.
When the pan and tilt reaches a scan limit stop, it reverses direction. Select preset 96 (29) to stop a scan. Any pan and tilt or lens
command also will stop a scan.
Temperature 37 C
98 F
Dewpoint 08 C
46 F
Pressure 10.30 psig
0.71 bar
Refresh