C311M-L (1/05) 59
00864
2. Open hinge door to the system. Remove the cap screw that secures the wiper
board. Unplug the ribbon cable connector.
00866
RIBBON CABLE CONNECTO
R
CAP SCREW
00865
3. Lift up wiper board and unplug the cartridge power cables. Let board dangle to the
side of the enclosure.
4. Lift cartridge out of the enclosure.
00867
PRESSURIZED IOC
IMPORTANT: Disconnect power to the Esprit system before removing or installing the pressurized cartridge. Software conflicts can occur
if the Esprit is not powered-down before removing/installing the IOC.
There are no user-serviceable parts internal to the pressurized integrated optics cartridge. If vessel fails, Pelco recommends that it be
returned to the factory for replacement or repair.
Removing the IOC
1. Remove the 4 Phillips screws located on the outside viewing window.