Pelco C2423M User Manual Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
NOTE:
Programming
preset 90 (23) disables the
manual limit stops until
preset 91 (24) is set.
NOTE:
On power-up, the
auto scan tilt angle will be
whatever angle the camera
was at when the right scan
limit was set.
TURNING LIMIT STOPS ON OR OFF
To change the limit stop mode:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Other.
3. Press the Iris Open button to enter the Other menu.
4. Position the cursor (>) beside Limit Stops.
5. Press the Iris Open button. The cursor moves to the right, beside the word On or Off.
6. Move the joystick up or down to toggle between On and Off.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
PROGRAMMING LIMIT STOPS
Manual Limit Stops
Refer to the documentation for your control system for programming presets, and then do
the following:
1. Make sure limit stops are turned ON, and then exit the menu.
2. Push the joystick left until you reach the limit you want the camera to go to on the left.
3. Program preset 90 (23).
4. Push the joystick right to the limit you want the camera to go to on the right.
5. Program preset 91 (24).
Setting presets 90 (23) and 91 (24) to the same point disables manual limit stops.
Scan Limit Stops
Refer to the documentation for your control system for programming presets, and then do
the following:
1. Make sure limit stops are turned ON, and then exit the menu.
2. Push the joystick left until you reach the limit you want the camera to go to on the left.
3. Program preset 92 (25).
4. Push the joystick right to the limit you want the camera to go to on the right.
5. Program preset 93 (26).
Setting presets 92 (25) and 93 (26) to the same point disables scan limit stops.
LINE SYNCHRONIZATION
Main Menu Line Sync Menu
<Camera>
<Line Sync>
<Power Up> Line sync On
<Aux> Line sync phase 0
<Alarms, Zone Blank> Exit
<Other>
EXIT
If cameras are out of phase with each other, they may produce what appears to be vertical roll
when switching between cameras.
There are two settings for line synchronization:
On - Adjust the synchronization of the power line voltage so that it is in phase with other
cameras.
Off - The dome synchronizes to an internal clock.
To change the line synchronization settings:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Line Sync.
3. Press the Iris Open button. The Line Sync menu appears.
4. Position the cursor (>) beside one of the choices. Press the Iris Open button.
LINE SYNC - The cursor moves to one of two choices: ON or OFF. Move the joystick up or
down to toggle between them. Press the Iris Open button to select the choice. If you changed to
OFF, the camera may reset itself as it adjusts to the new synchronization. If the camera resets,
it will only affect the line synchronization. It will not change any other camera parameters, such
as auto focus or auto iris. Press the Iris Close button if you do not want to change the setting.
Pelco Manual C2423M (5/00) 18
Page view 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 27 28

Comments to this Manuals

No comments