Programming Guide - Spectra II Color/Black & White
Gain/AGC Menu
1. Access main menu (preset 95).
2. Make main menu selections.
Joystick: Move up or down to position cursor or
to toggle between selections.
Iris Open: Enter
Iris Close: Cancel
PRESETS
The following presets are
reserved for special functions.
Preset Function
1 Park
1-7 Alarms, if used
33 Flip command
34 Pan zero
command
88 IR filter IN
89 IR filter OUT
90-91 Manual limit stops
92-93 Scan limit stops
95 Select camera
programming
menu
96 Stop a scan
97 Random scanning
98 Frame scanning
99 Start auto
scanning
For detailed instructions, refer to the following sections.
Menu items are listed alphabetically.
MAIN MENU
<Camera>
<Line Sync>
<Power Up>
<Aux>
<Alarms, Zone Blank>
<Other>
EXIT
Sharpness Menu
Sharpness 15
Exit
Camera Menu
Backlight comp Off
Zoom limit x72
Reset camera
<Gain/AGC>
<Auto-iris>
<Next>
Exit
Line Sync Menu
Line sync On
Line sync phase 0
Exit
Power-Up Menu
Power Up Default
Exit
Aux Menu
Aux 1 mode Normal
Aux 2 mode Normal
Exit
Alarms, Zone Blank Menu
Alarm resume Off
Alarm dwell sec 5
<Alarm priority>
<Alarm pattern>
<Zone blank>
Exit
Other Menu
Auto flip On
Proportional pan On
Limit stops Off
Park time minutes 0
Scan speed deg/s 25
Pattern length 1.5 min
Exit
AGC mode Auto
Gain 6
Exit
Auto-Iris Menu
Auto-iris mode Auto
Auto-iris level 7
Exit
Next Menu
Slow shutter mode Auto
Shutter speed Auto
Auto focus mode Auto
<IR Filter>
<Sharpness>
<White balance>
Previous
Exit
Alarm Priority Menu
Alarm 1 Low
2 Low
3 Low
4 Low
5 Low
6 Low
7 Low
Exit
Alarm Pattern Menu
Alarm 1No Pattern
2No Pattern
3No Pattern
4No Pattern
5No Pattern
6No Pattern
7No Pattern
Exit
Zone Blank Menu
Video Blank Zone 1Off
2Off
3Off
4Off
5Off
6Off
7Off
8Off
Exit
IR Filter Menu
IR Filter mode Auto
Auto IR Level Dusk
Exit
White Balance Menu
Auto white bal On
Red bal level - -
Blue bal level - -
Exit
Pelco Manual C2423M (5/00) 8