14 Pelco Manual C1456M-D (10/98)
Figure 4. Compass Tool Figure 5. Conduit Fitting Installation
ATTACH SAFETY CHAIN HERE
CAUTION:
Be careful
not to cut outside of the
line. If you do, you may not
be able to install the back
box. Also, the trim ring
may not cover the hole.
NOTE:
Use the SCA1 (structural
ceiling adapter) if additional support
is required.
3.0 INSTALLATION FOR IN-CEILING MODELS
To install the dome proceed through the steps in this section, beginning with Sec-
tion 3.1, “Ceiling and Back Box Preparation.”
3.1 CEILING AND BACK BOX PREPARATION
3.1.1 Hard Ceiling
1. Locate the center point where you want to drill a hole in the ceiling.
2. Drill a hole in the ceiling using a 3/32-inch drill bit.
3. Remove the compass tool from the parts bag that came with the back box
(refer to Figure 4). Press the stud of the compass tool into the hole in the
ceiling. Insert a pencil in the hole in the other end of the compass and mark a
circle on the ceiling.
4. Carefully cut the circle out of the ceiling.
5. Remove the conduit fitting, lock nut, and safety chain bracket from the parts
bag and attach them to the back box as shown in Figure 5.
Proceed to Section 3.2, WIRING.