Pelco HS4514 User Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
C1472M-E (1/07) 7
ENCLOSURE POWER
If the enclosure does not have a heater (model HS4514), proceed to the Camera Mounting section.
If your enclosure has a heater (models HS4514-1/-2), follow the steps below.
1. Add the camera wattage to the wattage of the heater. Refer to the Specifications section, for the heater wattage.
2. Determine the size of wire to use. If you are using 24 VAC, refer to Table A.
3. Bring wires for AC high, AC neutral, and ground into the enclosure. Refer to Figure 1 and Figure 2, and connect the wiring as follows:
a. Connect AC high to AC HI of the 3-connector terminal block.
b. Connect AC neutral to AC NT of the 3-connector terminal block.
c. Connect ground to GND of the 3-connector terminal block.
EXAMPLE: An enclosure that requires 30 VA and is installed 94 feet (28 m) from the transformer would require a minimum wire gauge of
20 AWG.
NOTE: Distances are calculated in feet; values in parentheses are meters.
Table A. 24 VAC Wiring Distances
The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10 percent voltage drop.
(Ten percent is generally the maximum allowable voltage drop for AC-powered devices.)
Wire Gauge
20 18 16 14 12 10
Total VA consumed
10
283
(86)
451
(137)
716
(218)
1142
(348)
1811
(551)
2880
(877)
Maximum distance from
transformer to load
20
141
(42)
225
(68)
358
(109)
571
(174)
905
(275)
1440
(438)
30
94
(28)
150
(45)
238
(72)
380
(115)
603
(183)
960
(292)
40
70
(21)
112
(34)
179
(54)
285
(86)
452
(137)
720
(219)
50
56
(17)
90
(27)
143
(43)
228
(69)
362
(110)
576
(175)
Page view 6