Pelco C3432M-F User Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
C3432M-F (6/08) 15
ALARM AND 24 VAC WIRES
CONNECTING A RELAY DEVICE
The IP110 Camclosure has an output for triggering an external device. It supports both momentary and
continuous relay operation.
You can operate the relay interactively, during an active connection, or automatically to coincide with
certain events. Typical applications include activating a door, gate or lock, or switching on lights or other
electrical devices.
Figure 9 shows how to wire the relay with its power source to the Camclosure.
Figure 9. Relay Wiring
NOTE: The green/white wire is internally connected to the camclosure chassis. Any connected signalling
device should be left floating with respect to the camclosure chassis, otherwise damage could result.
Table B. Wire Descriptions
Wire Color Description
Black 24 VAC (use only if PoE is not connected)
Red 24 VAC (use only if PoE is not connected)
Blue Alarm In
Blue/White Alarm In, Return
Green Relay Out
Green/White Relay Out, Return
WARNING: Do not exceed the maximum rating of 12 VDC, 0.15 A.
+
_
DC
CONNECTING A RELAY DEVICE
(CONNECTION EXAMPLE)
GREEN WIRE
GREEN / WHITE WIRE
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 39 40

Comments to this Manuals

No comments